Table of Contents

Paragon kiln

Overview

The Paragon SC3 is a compact, high-speed digital electric kiln located in the metalworking room. It is specifically designed for silver clay, glass fusing, enameling, and heat-treating small metal components. Its ceramic fiber firing chamber is lightweight and heats up rapidly, making it ideal for projects requiring precise temperature control and fast cycle times.

Machine Specifications

Link to product page

Operating Instructions

Before Starting

  1. Inspection: Check the fiber walls for cracks or loose elements. Ensure the floor is protected by a kiln shelf or kiln wash.
  2. Clearance: Maintain at least 300mm of clearance around the kiln. Ensure no flammable materials are on top of the unit.
  3. Venting: If firing silver clay or glass with glues, ensure the top vent plug is removed for the first phase of firing.

Programming & Operation

  1. Power Up: Turn on the main switch. The controller will display the current room temperature.
  2. Select Program: Use the digital controller to select a “User” program or a “Ramp-Hold” sequence.
  3. Load Work: Use tongs to place work on the kiln shelf. Do not place work directly on the fiber floor.
  4. Start Firing: Press 'Start'. Do not leave the kiln unattended during the initial ramp-up.
  5. Monitoring: Use the viewing window to check for “slumping” in glass or “glowing” in metal. Avoid opening the door unless necessary.

Shut Down

  1. Cooling: Allow the kiln to cool naturally to at least 150°C before removing work. Opening the door too early can damage the heating elements and your project.
  2. Power Off: Once cooled, turn off the controller and the main power isolation switch.
  3. Unload: Use heat-resistant gloves to remove the kiln shelf and place it on a heat-proof surface (e.g., a firebrick).

Safety & Induction

:!: Risk Score Amber

:!: Risk Assessment: Link

:!: Do I need an induction to use this machine? Yes

:!: Can I use this machine while lone working? Yes

PPE Required / Suggested / Banned
Eye protectionN/A
Hearing protectionN/A
GlovesRequired - High-heat Zetex or Kevlar gloves must be used when handling hot tongs or shelves.

Specific Hazards

Induction Information

:!: Do I need an induction to use this machine?: Yes

Maintenance History

Date next maintenance is due: 01/04/2026

Date Member ID Notes
01/10/2025 John O PAT test completed