User Tools

Site Tools


riskassessment:sm5v3ra

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
riskassessment:sm5v3ra [2022/11/19 15:22] – [2. Chipping of work material, flying debris, high temperature debris] jsullyriskassessment:sm5v3ra [2025/10/05 15:57] (current) – ↷ Links adapted because of a move operation jamesball
Line 1: Line 1:
 ====== Risk Assessment ====== ====== Risk Assessment ======
  
-^ Area assessment is taking place | [[equipment:metalbandsaw|Sealey SM5.v3 Horizontal Bandsaw]] Work Area ||+^ Area assessment is taking place | [[equipment:metalworking_room:metalbandsaw|Sealey SM5.v3 Horizontal Bandsaw]] Work Area ||
 ^ Assessment undertaken by ^ Person 1 | Jon Sully | ^ Assessment undertaken by ^ Person 1 | Jon Sully |
 |    ^ Person 2 |  | |    ^ Person 2 |  |
Line 8: Line 8:
 === Description of activity being assessed === === Description of activity being assessed ===
  
-General usage of the [[equipment:metalbandsaw|Sealey SM5.v3 Horizontal Bandsaw]].+General usage of the [[equipment:metalworking_room:metalbandsaw|Sealey SM5.v3 Horizontal Bandsaw]].
    
  
Line 18: Line 18:
   - Malfunction of machine   - Malfunction of machine
   - Unauthorised or improper use of machine   - Unauthorised or improper use of machine
 +  - Tripping hazard
  
 ===== 1. Contact with moving parts of machine ===== ===== 1. Contact with moving parts of machine =====
Line 54: Line 55:
 === Recommended Actions: === === Recommended Actions: ===
  
-  * Signage on entrance door to F11B instructing users not to enter when someone is actively operating the bandsaw+  * No actions
  
 ===== 4. Malfunction of machine ===== ===== 4. Malfunction of machine =====
Line 76: Line 77:
   * The machine is locked off when not in use with a padlocked power switch. The padlock has a combination code which is only shared with members once inductions are complete.   * The machine is locked off when not in use with a padlocked power switch. The padlock has a combination code which is only shared with members once inductions are complete.
   * Only appropriate methods and materials should be used when operating the machine.   * Only appropriate methods and materials should be used when operating the machine.
 +
 +=== Recommended Actions: ===
 +
 +  * No actions
 +
 +===== 6. Tripping hazard =====
 +
 +=== Controls Applied: ===
 +
 +  * The machine is on castors so can be moved to support different workloads. Induction should highlight the potential tripping hazard of the power cable, and how best to position the machine to avoid tripping hazards.
  
 === Recommended Actions: === === Recommended Actions: ===
riskassessment/sm5v3ra.1668871363.txt.gz · Last modified: by jsully